Problems needing attention in the working process of metal
1. The forward end of the metal circular saw blade, the proximity switch on the lateral clamping seat, and the saw blade cover should be set to ensure that all circular materials can correspond. It is not necessary to adjust the position of the backward end of the metal circular saw machine to fix it. It is not possible to adjust the position of the rear end to fix it, nor can it be adjusted.
2. When cutting square or irregular materials with a metal circular saw, move to the switch position held horizontally, loosen the screws, and adjust the fixing bracket according to the actual situation. For example, square materials of 15mm-60mm can be cut. During automatic operation of the equipment, do not adjust the LS sensing block. Debugging can only be carried out after the equipment is completely stopped, otherwise it is easy to find dangerous accidents!
3. Attention should be paid to cooling the circular saw blade: there is lubricating oil mist R68 on both ends of the metal circular saw blade, with a dripping rate of one drop every 10 seconds. Do not swallow oil mist. If it enters your mouth accidentally, please spit it out immediately. If it splashes into your eyes, immediately wash your eyes with plenty of water. In cold weather, it is necessary to prevent the oil mist from freezing and maintain the necessary temperature.